| Model 2315 Characteristics |
| | |
| Telemetry Channel Interface | |
Two Communication Ports 15 pin female D-Sub (DB15F) shielded Ports 1 and 2 | 150 to 64,000 bps Asynchronous Low Speed Protocol (LSP) Up to twelve 2315s report to a 2015 unit DTE (RS-422 or RS-232) |
| | |
| Craft Configuration Port | |
| 9 pin female D-Sub (DB9F) shielded | RS-232, 4800 baud 8/N/1, no parity, no flow control Embedded text configuration program Windows configuration program |
| | |
| LED Indicators | |
| | Unit power and unit fail status Port activity |
| | |
| Power | |
Input Power Range Power Consumption Power Connection | 18 to 56 VDC, floating 4 to 9 Watts Barrier Strip, two #6 screws (separate chassis ground strap) |
| | |
| Environmental | |
Operating Temperature Humidity Range Storage Temperature | 0 to +50° C 5% to 95%, Non-condensing -40 to +70° C |
| | |
| Physical Characteristics | |
Shelf Size Rack Mounting Shelf Weight | 1.75” H (1 RU), 19” W, 11” D Flush, 2” or 5 1/8” projection 5 pounds |
| | |
| Alarm Inputs | |
| 50 pin female Centronics/Champ | 32, optically isolated, 22 k to battery Programmable Alarm or Status Programmable delay Programmable Alarm on ground or on open |
| | |
| Control Outputs | |
| 50 pin female Centronics/Champ | 16, Form C relays Alarm summary output, Form A relay Momentary or Latching 1 amp max, 48V DC 0.6 amp max, 110V AC or DC |
| | |
| Analog Voltages (optional, field upgradeable) | |
| 25 pin female D-Sub (DB25F) shielded | 16, ground referenced, single-ended inputs (use pairs for up to 8 differential inputs, can use both single-ended and differential) (0 to 7.5, 15, 30, 60 or 120 VDC) Polarity and range set via software 52 k to ground, low pass filtered |
| | |